These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Glucagon-like peptide-1 (GLP-1) attenuates post-resuscitation myocardial microcirculatory dysfunction. Author: Dokken BB, Hilwig WR, Teachey MK, Panchal RA, Hubner K, Allen D, Rogers DC, Kern KB. Journal: Resuscitation; 2010 Jun; 81(6):755-60. PubMed ID: 20347207. Abstract: AIM OF THE STUDY: Post-resuscitation syndrome leads to death in approximately 2 out of every 3 successfully resuscitated victims, and myocardial microcirculatory dysfunction is a major component of this syndrome. The aim of this study was to determine if glucagon-like peptide-1 (GLP-1) improves post-resuscitation myocardial microcirculatory function. METHODS: Ventricular fibrillation (VF) was induced electrically in 20 anesthetized domestic swine (30-35 kg). Following 8 min of untreated VF, animals were resuscitated with aggressive advanced cardiac life support (ACLS). Animals were blindly randomized to receive a continuous infusion of either GLP-1 (10 pM/kg/min) or equal volume saline as placebo (PBO) for 4h, beginning 1 min after return of spontaneous circulation (ROSC). Left ventricular (LV) haemodynamics, LV ejection fraction, cardiac output, and coronary flow reserve (CFR) [using a standard technique of intracoronary Doppler flow measurements before and after intracoronary administration of 60 microg adenosine] were performed pre-arrest and at 1 and 4h post-resuscitation. In the present study, CFR is a measure of myocardial microcirculatory function since these swine had no obstructive coronary artery disease. Twenty-four hour post-resuscitation survival and neurological functional scores were also determined. RESULTS: CFR was significantly increased in GLP-1-treated animals, 1h (1.79+/-0.13 in control animals vs. 2.05+/-0.12 in GLP-1-treated animals, P = <0.05) and 4h (1.82+/-0.16 in control animals vs. 2.31+/-0.13 in GLP-1-treated animals, P = <0.05) after ROSC. In addition, compared to PBO-treated animals, GLP-1 increased cardiac output 1h after ROSC (2.1+/-0.1 in control animals vs. 2.7+/-0.2 in GLP-1-treated animals, P = <0.05). There was no statistically significant difference in survival between GLP-1-treated (100%) and PBO-treated animals (78%). CONCLUSIONS: In this swine model of prolonged VF followed by successful resuscitation, myocardial microcirculatory function was enhanced with administration of GLP-1. However, GLP-1 treatment was not associated with a clinically significant improvement in post-resuscitation myocardial function.[Abstract] [Full Text] [Related] [New Search]