These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Can plasma D-dimer predict the result of a ventilation-perfusion scan?
    Author: Grüning T, Khonsari M, Vivian GC, Nokes T.
    Journal: Clin Imaging; 2010; 34(3):179-84. PubMed ID: 20416481.
    Abstract:
    The use of plasma D-dimer assay has been advocated for the exclusion of pulmonary embolism. We retrospectively looked at 840 patients in whom both ventilation-perfusion scan and D-dimer assay were performed within 48 h. The negative predictive value of a negative D-dimer assay was 96% for emergency admissions and 98% for inpatients. We present the cases of two patients with negative D-dimer assay results who had a high-probability lung scan, and we have found a further three patients with negative D-dimer assay results who had an intermediate-probability lung scan.
    [Abstract] [Full Text] [Related] [New Search]