These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study.
    Author: Mehling I, Müller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM.
    Journal: J Hand Surg Am; 2010 Jun; 35(6):885-91. PubMed ID: 20513572.
    Abstract:
    PURPOSE: To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. METHODS: We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the proximal row; in group d, 7 locking screws were used, filling all screw holes in the distal and proximal rows of the plate. The proximal fragment was fixed with 3 screws. The specimens were loaded with 80 N under dorsal and volar bending and with 250 N axial loading. Finally, load to failure tests were performed. RESULTS: Group d had the highest mean stiffness, 429 N/mm under axial compression, and was statistically significantly stiffer than the other groups. Group b had a mean stiffness of 208 N/mm, followed by group a, with 177 N/mm. Group c showed only a mean stiffness of 83 N/mm under axial compression. There were no statistically significant differences under dorsal and volar bending. CONCLUSIONS: In this model of distal radial fractures, there was a difference regarding the stiffness and the placement of screws in the distal rows of a volar fixed-angle plate. Inserting screws in all available holes in the distal fragment offered the highest stability. Using only the proximal row with 3 screws created an unstable situation. Based on these findings, we recommend placing at least 4 screws in the distal fragment and assigning at least 2 screws to the distal row of the multidirectional screw-holes.
    [Abstract] [Full Text] [Related] [New Search]