Search MEDLINE/PubMed
Title: [Determination of arsanilic acid and sulfanilic acid as adulterant in feed additives by reversed-phase high performance liquid chromatography]. Author: Xu J, He H, Xu M, Qu Y. Journal: Se Pu; 2010 Feb; 28(2):218-20. PubMed ID: 20556965. Abstract: A reversed-phase high performance liquid chromatographic (RP-HPLC) method was established for the determination of arsanilic acid and sulfanilic acid as adulterant in the feed additives. The separation was carried out on a Waters Bondapak C18 column, and methanol-water (pH 2.9 adjusted by 0.01 mol/L phosphoric acid) (1 : 4, v/v) was used as the mobile phase with a flow rate of 1.0 mL/min. A diode array detector was used at 244 nm as the detection wavelength. Arsanilic acid and sulfanilic acid were separated within 3 min. The linear ranges all were 5 - 200 mg/L and the detection limits (S/N = 3) were 0.20 and 0.15 mg/L for arsanilic acid and sulfanilic acid, respectively. This method is simple and rapid, and suitable for the simultaneous determination of arsanilic acid and sulfanilic acid in feed additives.[Abstract] [Full Text] [Related] [New Search]