These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Manikin study of fibreoptic-guided intubation through the classic laryngeal mask airway with the Aintree intubating catheter vs the intubating laryngeal mask airway in the simulated difficult airway. Author: Heard AM, Lacquiere DA, Riley RH. Journal: Anaesthesia; 2010 Aug; 65(8):841-7. PubMed ID: 20586746. Abstract: In this randomised crossover manikin study of simulated difficult intubation, 26 anaesthetists attempted to intubate the trachea using two fibreoptic-guided techniques: via a classic laryngeal mask airway using an Aintree intubating catheter and via an intubating laryngeal mask airway using its tracheal tube. Successful intubation was the primary endpoint, which was completed successfully in all 26 cases using the former technique, and in 5 of 26 cases using the latter (p < 0.0001). The former technique also proved quicker to reach the vocal cords with the fibrescope (median (IQR [range])) time 18 (14-20 [8-44]) s vs 110 (70-114 [30-118]) s, respectively; p = 0.008); and to first ventilation (93 (74-109 [52-135]) s vs 135 (79-158 [70-160]) s, respectively; p = 0.0038)]. We conclude that in simulated difficult intubation, fibreoptic intubation appears easier to achieve using a classic laryngeal mask airway and an Aintree intubating catheter than through an intubating laryngeal mask airway.[Abstract] [Full Text] [Related] [New Search]