These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Optimal thoracic and lumbar spine imaging for trauma: are thoracic and lumbar spine reformats always indicated?
    Author: Mancini DJ, Burchard KW, Pekala JS.
    Journal: J Trauma; 2010 Jul; 69(1):119-21. PubMed ID: 20622586.
    Abstract:
    BACKGROUND: Computed tomography (CT) of the thoracic and lumbar (T/L) spine with reformats has become the imaging modality of choice for the identification of T/L spine fractures. The objective of this study was to directly compare chest/abdomen/pelvis CT (CAP CT) with CT with T/L reformats (T/L CT) for the identification of T/L spine fractures. METHODS: Patients who had both a CAP CT scan (5-mm imaging spacing) and T/L CT reconstruction (2.5-mm image spacing with sagittal and coronal reformats) were selected. A "fracture" group (N = 35) and a "no fracture" group (N = 57) were identified. The type and level of fracture were recorded. RESULTS: The CAP CT correctly identified all 35 patients with a thoracolumbar fracture (100% sensitivity; 95% confidence interval: 88-100%). A total of 80 separate fracture sites were present in the 35 patients. The CAP CT accurately identified 78 of those fractures (97.5% sensitivity; 95% confidence interval: 90.4-99.6%). The two fractures not identified on the CAP CT were both the transverse process fractures in patients with multiple fractures at different levels. CONCLUSION: Patients who have a CAP CT do not require reformats for clearance of the T/L spine.
    [Abstract] [Full Text] [Related] [New Search]