These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Peritoneal dialysis outflow failure from omental wrapping diagnosed by catheterography.
    Author: Xie JY, Ren H, Kiryluk K, Chen N.
    Journal: Am J Kidney Dis; 2010 Nov; 56(5):1006-11. PubMed ID: 20630641.
    Abstract:
    Peritoneal dialysis outflow failure caused by omental wrapping is a serious complication that is difficult to diagnose noninvasively. We report a case of outflow failure in which catheterography showed several characteristics of omental wrapping: "pseudocele" formation, delayed catheter emptying, and uneven distribution of contrast in the abdominal cavity. A laparoscopic procedure was performed with identification of peritoneal adhesion and greater omental wrapping. The catheter was stripped from the omentum and repositioned in the Douglas peritoneal sac. Catheterography is a reliable, safe, noninvasive, and inexpensive alternative procedure to diagnose outflow failure caused by omental wrapping.
    [Abstract] [Full Text] [Related] [New Search]