These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension.
    Author: Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H.
    Journal: Crit Care Med; 2010 Sep; 38(9):1824-9. PubMed ID: 20639753.
    Abstract:
    OBJECTIVES: The passive leg-raising maneuver is a reversible fluid-loading procedure used to predict fluid responsiveness in mechanically ventilated patients. The aim of the present study was to determine whether intra-abdominal hypertension (which impairs venous return) reduces the ability of passive leg raising to detect fluid responsiveness in critically ill ventilated patients. DESIGN: A prospective study. SETTING: The medical and surgical intensive care unit of a university medical center. PATIENTS: Forty-one mechanically ventilated patients with a pulse pressure variation of >12%. INTERVENTIONS: Stroke volume was continuously monitored by esophageal Doppler. Intra-abdominal pressure was measured via bladder pressure. After a passive leg-raising maneuver and a return to baseline, fluid loading with 500 mL of saline was performed. Hemodynamic parameters were recorded at each step. Nonresponders to volume loading were not analyzed (10 patients). Thirty-one patients were classified into two groups according to their response to passive leg raising: responders to passive leg raising (at least a 12% increase in stroke volume) and nonresponders to passive leg raising. MEASUREMENTS AND MAIN RESULTS: Sixteen patients (52%) were responders to passive leg raising, and 15 (48%) were nonresponders to passive leg raising (i.e., false negatives). At baseline, the median intra-abdominal pressure was significantly higher in the nonresponders to passive leg raising than in the responders to passive leg raising (20 [6.5] vs. 11.5 [5.5], respectively; p < .0001). The area under the receiver-operating characteristic curve was 0.969 +/- 0.033. An intra-abdominal pressure cutoff value of 16 mm Hg discriminated between responders to passive leg raising and nonresponders to passive leg raising with a sensitivity of 100% (confidence interval, 78-100) and a specificity of 87.5% (confidence interval, 61.6-98.1). An intra-abdominal pressure of > or =16 mm Hg was the only independent predictor of nonresponse to passive leg raising in a multivariate analysis (odds ratio, 2.6 [confidence interval, 1.1-6.6]; p = .04). CONCLUSIONS: An intra-abdominal pressure of > or =16 mm Hg seems to be responsible for false negatives to passive leg raising. Hence, the intra-abdominal pressure should be measured in critically ill ventilated patients, especially before performing passive leg raising.
    [Abstract] [Full Text] [Related] [New Search]