These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Adaptive removal of motion artifact from ECG based on impedance detection].
    Author: Lin S, Lai L, Wu X.
    Journal: Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Jun; 27(3):529-32, 543. PubMed ID: 20649012.
    Abstract:
    Motion artifact is a significant source of noise in ambulatory physiologic signals and can affect the diagnoses seriously. To cope with this problem, we adopted certain methods for removing motion artifact from ECG signals via synchronous acquisition of the elector/skin impedance as the reference signal of adaptive filter. The results demonstrated that 3rd order RLS adaptive filter can remove the baseline shift effectively with an exciting current of 120 Hz and 50 microA. Such system was implemented to investigate the utility of ambulatory heart rate monitoring, which provides convenient and reliable monitoring services for patients.
    [Abstract] [Full Text] [Related] [New Search]