These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Image-guided frameless stereotactic needle biopsy in awake patients without the use of rigid head fixation.
    Author: Amin DV, Lozanne K, Parry PV, Engh JA, Seelman K, Mintz A.
    Journal: J Neurosurg; 2011 May; 114(5):1414-20. PubMed ID: 20722608.
    Abstract:
    OBJECT: Image-guided frameless stereotactic techniques provide an alternative to traditional head-frame fixation in the performance of fine-needle biopsies. However, these techniques still require rigid head fixation, usually in the form of a head holder. The authors report on a series of fine-needle biopsies and brain abscess aspirations in which a frameless technique was used with a patient's head supported on a horseshoe headholder. To validate this technique, they performed an in vitro accuracy study. METHODS: Forty-eight patients underwent fine-needle biopsy of intracranial lesions that ranged in size from 0.9 to more than 107.7 ml; a fiducial-less, frameless, image-guided technique was used without rigid head fixation. In 1 of the 48 patients a cerebral abscess was drained. The accuracy study was performed with a skull phantom that was imaged with a CT scanner and tracked with a registration mask containing light-emitting diodes. The objective was a skin fiducial marker with a 4-mm circular target to accommodate the 2.5-mm biopsy needle. A series of 50 trials was conducted. RESULTS: Diagnostic tissue was obtained on the first attempt in 47 of 48 brain biopsy cases. In 2 cases small hemorrhages at the biopsy site were noted as a complication on the postoperative CT scan. One of these hemorrhages resulted in hand and arm weakness. The accuracy study demonstrated a 98% success rate of the biopsy needle passing through the 4-mm circular target using the registration mask as the registration and tracking device. This demonstrates a ± 0.75-mm tolerance on the targeting method. CONCLUSIONS: The accuracy study demonstrated the ability of the mask to actively track the target and allow navigation to a 4-mm-diameter circular target with a 98% success rate. The frameless, pinless, fiducial-less technique described herein will likely be another safe, fast alternative to frame-based stereotactic techniques for fine-needle biopsy that avoids the potential morbidity of rigid head-pin fixation. Furthermore, it should lend itself to other image-guided applications such as the placement of ventricular catheters for shunting or Ommaya reservoirs.
    [Abstract] [Full Text] [Related] [New Search]