These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Site-specific differences in latency intervals during biventricular pacing: impact on paced QRS morphology and echo-optimized V-V interval. Author: Herweg B, Ali R, Ilercil A, Madramootoo C, Cutro R, Weston MW, Barold SS. Journal: Pacing Clin Electrophysiol; 2010 Nov; 33(11):1382-91. PubMed ID: 20735713. Abstract: OBJECTIVE: To investigate differences in latency intervals during right ventricular (RV) pacing and left ventricular (LV) pacing from the (postero-)lateral cardiac vein in cardiac resynchronization therapy (CRT) patients and their relationship to echo-optimized interventricular (V-V) intervals and paced QRS morphology. METHODS: We recorded digital 12-lead electrocardiograms in 40 CRT patients during RV, LV, and biventricular pacing at three output settings. Stimulus-to-earliest QRS deflection (latency) intervals were measured in all leads. Echocardiographic atrioventricular (AV) and V-V optimization was performed using aortic velocity time integrals. RESULTS: Latency intervals were longer during LV (34 ± 17, 29 ± 15, 28 ± 15 ms) versus RV apical pacing (17 ± 8, 15 ± 8, 13 ± 7 ms) for threshold, threshold ×3, and maximal output, respectively (P < 0.001), and shortened with increased stimulus strength (P < 0.05). The echo-optimized V-V interval was 58 ± 31 ms in five of 40 (12%) patients with LV latency ≥ 40 ms compared to 29 ± 20 ms in 35 patients with LV latency < 40 ms (P < 0.01). During simultaneous biventricular pacing, four of five (80%) patients with LV latency ≥ 40 ms exhibited a left bundle branch block (LBBB) pattern in lead V(1) compared to three of 35 (9%) patients with LV latency < 40 ms (P < 0.01). After optimization, all five patients with LV latency ≥ 40 ms registered a dominant R wave in lead V(1) . CONCLUSIONS: LV pacing from the lateral cardiac vein is associated with longer latency intervals than endocardial RV pacing. LV latency causes delayed LV activation and requires V-V interval adjustment to improve hemodynamic response to CRT. Patients with LV latency ≥ 40 ms most often display an LBBB pattern in lead V(1) during simultaneous biventricular pacing, but a right bundle branch block after V-V interval optimization.[Abstract] [Full Text] [Related] [New Search]