These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Effectiveness comparison between open reduction combined with internal fixation and artificial radial head replacement in treating Mason type-III comminuted fractures of radial head].
    Author: Liu B, Lin Z, Cao L, Kang Y.
    Journal: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2010 Aug; 24(8):900-3. PubMed ID: 20839431.
    Abstract:
    OBJECTIVE: To compare the effectiveness between open reduction combined with internal fixation and artificial radial head replacement in treating Mason type-III comminuted fracture of radial head, to provide the evidence for available treatment methods. METHODS: Between January 2004 and June 2008, 65 cases of Mason type-III comminuted fractures were treated with open reduction, AO mini plate and screw system or a combination of Kirschner treatment (internal fixation group, n = 35) and with artificial radial head replacement (replacement group, n = 30). In internal fixation group, there were 21 males and 14 females with an age range of 21 to 35 years (mean, 30.7 years); the causes of injury were traffic accident in 12 cases, falling from height in 8 cases, and a fall in 15 cases; the locations were left side in 23 cases and right side in 12 cases; and the time between injury and surgery was 1-7 days (mean, 3 days). In replacement group, there were 19 males and 11 females with an age range of 23 to 67 years (mean, 32.5 years); the causes of injury were traffic accident in 7 cases, falling from height in 8 cases, and a fall in 15 cases; the locations were left side in 17 cases and right side in 13 cases; and the time between injury and surgery was 1-6 days (mean, 1.5 days). There was no significant difference in gender, age, disease cause, disease duration, or other general information between 2 groups (P > 0.05), so that 2 series of patients had comparability. RESULTS: Incisions healed primarily in 2 groups. All patients were followed up 1 to 4 years with an average of 2.5 years. There were significant differences in elbow flexion angle, extension angle, and forearm rotation angle between 2 groups (P < 0.05), but no significant difference in elbow pronation or supination weakness (P > 0.05). In internal fixation group, primary union occurred in 29 cases, delayed union in 2 cases, nonunion with ectopic ossification in 2 cases, and internal fixation failure in 2 cases. In replacement group, elbow flexion angle lost beyond 30 degrees in 1 case after 1 year, elbow stiffness occurred in 1 case because prosthesis was too long. According to Broberg and Morrey elbow scores system, the scores were 69.51 +/- 10.23 in internal fixation group and 81.55 +/- 12.06 in replacement group, showing significant difference (P < 0.05). The results were excellent in 15 cases, good in 5 cases, fair in 11 cases, and poor in 4 cases with an excellent and good rate of 57.1% in internal fixation group; the results were excellent in 17 cases, good in 5 cases, fair in 6 cases, and poor in 2 cases with an excellent and good rate of 73.3%. CONCLUSION: Artificial radial head replacement can achieve better joint function compared with open reduction combined with internal fixation in treating Mason type-III comminuted fractures of radial head.
    [Abstract] [Full Text] [Related] [New Search]