Title: Gold vs. platinum-iridium tip catheter for cavotricuspid isthmus ablation: the AURUM 8 study. Author: Lewalter T, Weiss C, Spencker S, Jung W, Haverkamp W, Willems S, Deneke T, Kautzner J, Wiedemann M, Siebels J, Pitschner HF, Hoffmann E, Hindricks G, Zabel M, Vester E, Schwacke H, Mittmann-Braun E, Lickfett L, Hoffmeister S, Proff J, Mewis C, Bauer W, AURUM 8 Study Investigators. Journal: Europace; 2011 Jan; 13(1):102-8. PubMed ID: 20876601. Abstract: AIMS: Gold electrodes have the theoretical advantage of creating bigger lesions than platinum-iridium (Pt-Ir) electrodes. We performed a prospective randomized study to compare the clinical efficacy of standard 8 mm Pt-Ir tip catheter (control) and 8 mm gold-tip catheters in the ablation of the cavotricuspid isthmus (CTI)-dependent atrial flutter. METHODS AND RESULTS: A total of 463 patients undergoing CTI ablation in 19 clinical centres were randomized to receive the treatment by gold-tip or control catheter. The primary endpoint was cumulative radiofrequency (RF) application duration until achieving bidirectional CTI block. It did not differ significantly for the two catheters. The gold-tip catheter was, however, associated with a higher ablation success rate (94.3 vs. 89.0%, P = 0.042) and a substantially lower incidence of char and coagulum formation (4.8 vs. 37.9%, P < 0.001), which required exchange of 1 gold-tip (0.4%) and 10 control catheters (4.6%, P = 0.005). The gold-tip catheter delivered more mean power (52 ± 12 W) than the control catheter (48 ± 13 W, P < 0.001). Both mean and maximum temperatures measured by the thermocouple integrated in the catheter tip were statistically significantly lower in the gold (mean: 53.2 ± 4.7°C, max: 68.7 ± 6.6°C) than in the control catheter (54.3 ± 5.2 and 70.2 ± 7.0°C, respectively, P < 0.05). Fluoroscopy time, procedure duration, procedural-related complications, and arrhythmia recurrence during 6 months of follow-up did not differ between the two catheters. CONCLUSION: Owing to a higher primary ablation success rate and reduced incidence of char/coagulum formation, gold may be preferred over Pt-Ir as electrode material for 8 mm tip catheters for CTI ablation. ClinicalTrials.gov: NCT00326001 (http://clinicaltrials.gov/ct2/show/NCT00326001).[Abstract] [Full Text] [Related] [New Search]