These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Some comments on the usefulness of measuring cardiac output by dye dilution.
    Author: de Leeuw PW, Birkenhäger WH.
    Journal: Eur Heart J; 1990 Dec; 11 Suppl I():13-6. PubMed ID: 2092982.
    Abstract:
    In this paper, a few aspects of the dye dilution method for measuring cardiac output are described. Data obtained with this technique show good reproducibility, although any first determination tends to be higher than subsequent ones. The method has been found to be useful in the assessment of cardiac function in, for instance, hypertensive patients. An additional advantage is that it can be used also in exercising subjects. As the dye dilution technique still is considered to be the standard method, other methods, such as thermodilution, should always be validated in comparison with the dye dilution technique.
    [Abstract] [Full Text] [Related] [New Search]