These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: A 5-year comparison of EVAR for large and small aortic necks. Author: Jim J, Rubin BG, Geraghty PJ, Criado FJ, Fajardo A, Sanchez LA. Journal: J Endovasc Ther; 2010 Oct; 17(5):575-84. PubMed ID: 20939711. Abstract: PURPOSE: To compare the long-term outcomes of endovascular aneurysm repair (EVAR) using the Talent endograft for abdominal aortic aneurysms (AAAs) with large and small aortic necks. METHODS: Data on 156 patients (142 men; mean age 74.1 years, range 41-89) with adequate preoperative imaging were obtained from the prospective, nonrandomized, multicenter Talent eLPS trial, which enrolled patients from February 2002 to April 2003. Subgroup analyses were performed for AAAs with a large aortic neck diameter (≥28 mm; n=53, group 1) and those with smaller necks (<28 mm; n=103, group 2). Safety and effectiveness endpoints were evaluated at 30 days, 1 year, and 5 years post procedure. RESULTS: Patients in both groups had similar gender and risk factor profiles. However, group 1 was significantly older (mean age 76.5 versus 72.9 years; p<0.01). Aside from neck diameter, the 2 groups had similar mean neck length and angulation. Group 1 also had a larger maximum aneurysm diameter (mean 58.2 versus 53.4 mm; p<0.01). At 1 year, the 2 groups had similar effectiveness endpoint results. There was a significantly lower freedom from major adverse events (MAEs) for group 1 at 30 days (79.2% versus 95.1%; p<0.01). While this trend continued to 1 year, the difference lost statistical significance (72.0% versus 85.1%; p=0.08). Freedom from all-cause mortality at 30 days (94.4% versus 100%; p<0.04) and aneurysm-related death at 1 year (93.3 versus 100%; p<0.04) also was significantly lower for group 1. At 5 years, there were no significant differences in the rates of endoleaks or aneurysm changes. The 5-year rates for freedom from aneurysm-related mortality for groups 1 and 2 were 91.2% and 98.7% (p=NS), respectively. There were 5 instances of migration in this study, all occurring in group 1 patients. CONCLUSION: AAAs with aortic necks ≥28 mm can be treated with endovascular devices with acceptable results at 5 years. However, these patients have a higher rate of MAEs within the first year and higher migration rates at 5 years. In addition, they have a lower freedom from all-cause mortality at 30 days and aneurysm-related death at 1 year. Careful patient selection, accurate device deployment, and continued follow-up are necessary to optimize long-term results in this patient population.[Abstract] [Full Text] [Related] [New Search]