These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Open lung approach associated with high-frequency oscillatory or low tidal volume mechanical ventilation improves respiratory function and minimizes lung injury in healthy and injured rats. Author: Krebs J, Pelosi P, Tsagogiorgas C, Zoeller L, Rocco PR, Yard B, Luecke T. Journal: Crit Care; 2010; 14(5):R183. PubMed ID: 20946631. Abstract: INTRODUCTION: To test the hypothesis that open lung (OL) ventilatory strategies using high-frequency oscillatory ventilation (HFOV) or controlled mechanical ventilation (CMV) compared to CMV with lower positive end-expiratory pressure (PEEP) improve respiratory function while minimizing lung injury as well as systemic inflammation, a prospective randomized study was performed at a university animal laboratory using three different lung conditions. METHODS: Seventy-eight adult male Wistar rats were randomly assigned to three groups: (1) uninjured (UI), (2) saline washout (SW), and (3) intraperitoneal/intravenous Escherichia coli lipopolysaccharide (LPS)-induced lung injury. Within each group, animals were further randomized to (1) OL with HFOV, (2) OL with CMV with "best" PEEP set according to the minimal static elastance of the respiratory system (BP-CMV), and (3) CMV with low PEEP (LP-CMV). They were then ventilated for 6 hours. HFOV was set with mean airway pressure (PmeanHFOV) at 2 cm H2O above the mean airway pressure recorded at BP-CMV (PmeanBP-CMV) following a recruitment manoeuvre. Six animals served as unventilated controls (C). Gas-exchange, respiratory system mechanics, lung histology, plasma cytokines, as well as cytokines and types I and III procollagen (PCI and PCIII) mRNA expression in lung tissue were measured. RESULTS: We found that (1) in both SW and LPS, HFOV and BP-CMV improved gas exchange and mechanics with lower lung injury compared to LP-CMV, (2) in SW; HFOV yielded better oxygenation than BP-CMV; (3) in SW, interleukin (IL)-6 mRNA expression was lower during BP-CMV and HFOV compared to LP-CMV, while in LPS inflammatory response was independent of the ventilatory mode; and (4) PCIII mRNA expression decreased in all groups and ventilatory modes, with the decrease being highest in LPS. CONCLUSIONS: Open lung ventilatory strategies associated with HFOV or BP-CMV improved respiratory function and minimized lung injury compared to LP-CMV. Therefore, HFOV with PmeanHFOV set 2 cm H2O above the PmeanBP-CMV following a recruitment manoeuvre is as beneficial as BP-CMV.[Abstract] [Full Text] [Related] [New Search]