These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of benzimidazole residues in bovine milk by ultra-high performance liquid chromatography-tandem mass spectrometry.
    Author: Xia X, Dong Y, Luo P, Wang X, Li X, Ding S, Shen J.
    Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Nov 15; 878(30):3174-80. PubMed ID: 20956094.
    Abstract:
    A method based on ultra-high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UHPLC-MS/MS) for the simultaneous determination of benzimidazole residues in bovine milk has been optimized and validated. Rapid chromatographic separation of 13 analytes in 8 min was obtained by means of UHPLC. The samples were subject to Oasis MCX solid-phase extraction cartridges for extraction and clean-up. Matrix-matched calibration curves were performed to compensate for the matrix effect and loss in sample preparation. Mean recoveries ranged from 80% to 101% and inter-day precision was lower than 14%. Limit of detection and limit of quantification of the method ranged from 0.01 to 0.5 μg L⁻¹ and from 0.1 to 1.0 μg L⁻¹, respectively.
    [Abstract] [Full Text] [Related] [New Search]