These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Transcutaneous monitoring as a replacement for arterial PCO(2) monitoring during nocturnal non-invasive ventilation. Author: Storre JH, Magnet FS, Dreher M, Windisch W. Journal: Respir Med; 2011 Jan; 105(1):143-50. PubMed ID: 21030230. Abstract: BACKGROUND: Continuous, non-invasive assessment of alveolar ventilation achieved by transcutaneous PCO(2) (PtcCO(2)) monitoring is clearly superior to intermittent, invasive blood gas analyses in patients receiving nocturnal non-invasive positive pressure ventilation (NPPV), but the reliability and accuracy of PtcCO(2)-monitoring is still disputed. The present study was aimed at investigating the capability of modern PtcCO(2)-monitoring to reliably assess alveolar ventilation during nocturnal NPPV. METHODS: Capillary blood gas measurements (11pm, 2am, 5am and 7am) and 8 h of continuous PtcCO(2)-monitoring using three of the latest generation devices (SenTec Digital Monitor, Radiometer TCM4-TINA and Radiometer TOSCA500) were performed during polysomnography-proven sleep studies in 24 patients receiving NPPV (15 with COPD, 9 with restrictive disorders). RESULTS: The technical calibration drift for SenTec DM, TCM4-TINA and TOSCA500 was 0.1, -0.4 and -0.5 mmHg/h, respectively. Bland-Altman method comparison of PaCO(2)/drift-uncorrected PtcCO(2) revealed a mean bias (limits of agreement) of 1.0 (-4.7 to 6.7), -1.5 (-15.6 to 12.5) and 0.8 (-6.8 to 8.3) mmHg, respectively. Continuous overnight PtcCO(2)-monitoring detected variations in alveolar ventilation, with median ranges of 12.3 (10.7-14.5) mmHg for SenTec DM, 14.5 (12.5-17.0) mmHg for TCM4-TINA and 11.5 (11.0-13.0) mmHg for TOSCA500 (RM-ANOVA, p < 0.001). The four capillary PaCO(2) values ranged by a median of 6.3 (4.7-9.7) mmHg. CONCLUSIONS: Modern PtcCO(2)-monitoring is reliable, accurate and robust. Since PtcCO(2)-monitoring is also non-invasive, does not disrupt sleep quality and provides a more complete picture of alveolar ventilation than intermittent capillary PaCO(2), PtcCO(2)-monitoring should become the preferred technique for assessing alveolar ventilation during nocturnal NPPV. TRIAL REGISTRATION: DRKS00000433 at http://apps.who.int/trialsearch/default.aspx.[Abstract] [Full Text] [Related] [New Search]