These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Computed tomography to identify preoperative guidelines for internal fixation of the distal sesamoid bone in horses: an in vitro study. Author: Perrin R, Launois T, Brogniez L, Desbrosse FG, Coomer RP, Clegg PD, Reda AA, Gehin SG, Vandeweerd JM. Journal: Vet Surg; 2010 Dec; 39(8):1030-6. PubMed ID: 21077919. Abstract: OBJECTIVE: To assess the reliability of computed tomography (CT) to identify the direction of implant insertion for cortical screws along the longitudinal axis of intact (nonfractured) distal sesamoid bones. STUDY DESIGN: In vitro study. SAMPLE POPULATION: Cadaveric paired equine forelimbs (n=16). METHODS: Insertion of a cortical screw in lag fashion along the longitudinal axis of intact (nonfractured) distal sesamoid bones was evaluated in 2 groups (3.5 and 4.5 mm) of 8 paired limbs. In each group, the direction of the distal sesamoid bone was determined by CT (Equine XTC 3000 pQCT scanner). Screw placement was verified by specimen dissection. Implant direction was considered satisfactory if the entire screw length was within the distal sesamoid bone and not damaging the articular or flexural surfaces. RESULTS: In our sample and according to our criteria, the proportion of satisfactory direction of screws was 0.63 (5/8) for 4.5 mm implants, and 0.87 (7/8) for 3.5 mm implants. CONCLUSIONS: CT is a useful imaging modality to identify anatomic landmarks for insertion of a 3.5 mm cortical screw in the distal sesamoid bone.[Abstract] [Full Text] [Related] [New Search]