These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Low-dose 18F-FDG PET/CT enterography: improving on CT enterography assessment of patients with Crohn disease.
    Author: Shyn PB, Mortele KJ, Britz-Cunningham SH, Friedman S, Odze RD, Burakoff R, Goldberg JE, Erturk M, Silverman SG.
    Journal: J Nucl Med; 2010 Dec; 51(12):1841-8. PubMed ID: 21078803.
    Abstract:
    UNLABELLED: The purpose of this study was to evaluate the diagnostic efficacy of low-dose, combined (18)F-FDG PET/CT enterography (PET/CTE), compared with CT enterography (CTE) alone, in the assessment of patients with Crohn disease. METHODS: Thirteen patients with Crohn disease were prospectively enrolled in this pilot study and underwent abdominal-pelvic (18)F-FDG PET/CTE using neutral oral and intravenous contrast medium. The effective dose from PET/CTE was 17.7 mSv for the first 4 patients and 8.31 mSv for the last 9 patients. Six patients underwent surgical resection of the bowel, and 7 patients underwent colonoscopy with biopsies within 27 d (mean, 12 d) of PET/CTE. PET/CTE and CTE images were each visually assessed for Crohn disease involvement in 54 bowel segments with pathology correlation. Extraintestinal findings were recorded. A CTE severity score, maximum standardized uptake value (SUVmax), SUVmax ratio, simplified endoscopic score, and clinical parameters were correlated with pathology inflammation grade, on a per-patient basis and on a per-bowel-segment basis, using Spearman correlation. RESULTS: In 3 (23.1%) of 13 patients, (18)F-FDG uptake using PET/CTE revealed active inflammation in a bowel segment not evident using CTE (n = 2) or revealed an enterocolic fistula missed with CTE (n = 1). Visual interpretation of both PET/CTE and CTE images detected the presence of disease in all bowel segments with more than mild inflammation (sensitivity, 100%; specificity, 89.7%; positive predictive value, 78.9%; and negative predictive value, 100%). Correlation to inflammation grade per patient was the strongest for the SUVmax ratio (0.735, P = 0.004) and SUVmax (0.67, P = 0.013), as compared with the CTE score (0.62, P = 0.024). Correlation with inflammation per bowel segment was higher for the CTE score (0.79, P < 0.0001) than the SUVmax ratio (0.62, P < 0.0001) or SUVmax (0.48, P < 0.0001). SUVmax correlated strongly with serum C-reactive protein (0.82, P = 0.023), but CTE score did not. CONCLUSION: Low-dose (18)F-FDG PET/CTE, compared with CTE, may improve the detection and grading of active inflammation in patients with Crohn disease. PET/CTE also may reveal clinically significant findings, such as enterocolic fistula, not evident on PET or CTE alone.
    [Abstract] [Full Text] [Related] [New Search]