These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Three-dimensional finite element analysis of biomechanical characteristics of cancellous screw in different bone densities].
    Author: Tian C, Zhang MC, Ouyang J.
    Journal: Nan Fang Yi Ke Da Xue Xue Bao; 2010 Nov; 30(11):2466-8. PubMed ID: 21097407.
    Abstract:
    OBJECTIVE: To predict the cancellous screw stress distributions and pull-out strength in cancellous bone with different densities using 3-D finite element analysis and provide biomechanical evidence for screw implant in clinical practices. METHODS: Three-dimensional models of bones with low, medium and high bone density and a fixation screw were generated in Solidworks. Finite element analysis was performed after importing these models to Abaqus to simulate the pull- out process. RESULTS: Stress concentrated both at the surfaces where major diameter of the screw connected the bone and at the proximal half angle of the 3 proximal screw threads. Maximum Von Mises stress of the threads decreased along the long axis of the screw. The pull-out strengths of the cancellous screw were 208.9 N, 431.45 N, and 648.80 N in low, medium and high bone density, respectively. CONCLUSION: During the pull-out process of cancellous screw, stress concentrates at the proximal end of the screw and the pull-out strengths are proportional to the cancellous bone density.
    [Abstract] [Full Text] [Related] [New Search]