  • Title: Measurement of wind noise levels in streamlined probes.
    Author: Webster J, Raspet R, Yu J, Prather WE.
    Journal: J Acoust Soc Am; 2010 May; 127(5):2764-70. PubMed ID: 21117725.
    Abstract:
    This paper investigates the wind noise pressure spectra measured by aerodynamically designed devices in turbulent flow. Such measurement probes are often used in acoustic measurements in wind tunnels to reduce the pressure fluctuations generated by the interaction of the devices with the incident flow. When placed in an outdoor turbulent environment however, their performance declines noticeably. It is hypothesized that these devices are measuring the stagnation pressures generated by the cross flow components of the turbulence. Predictions for the cross flow contribution to the stagnation pressure spectra based on measured velocity spectra are developed, and are then compared to the measured pressure spectra in four different probe type devices in windy conditions outdoors. The predictions agree well with the measurements and show that the cross flow contamination coefficient is on the order of 0.5 in outdoor turbulent flows in contrast to the published value of 0.15 for measurements in a turbulent jet indoors.
    [Abstract] [Full Text] [Related] [New Search]