These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Non-invasive diagnosis and grading of postsurgical endoscopic recurrence in Crohn's disease: usefulness of abdominal ultrasonography and (99m)Tc-hexamethylpropylene amineoxime-labelled leucocyte scintigraphy.
    Author: Paredes JM, Ripollés T, Cortés X, Reyes MD, López A, Martínez MJ, Moreno-Osset E.
    Journal: J Crohns Colitis; 2010 Nov; 4(5):537-45. PubMed ID: 21122557.
    Abstract:
    UNLABELLED: Non-invasive techniques aim to be an alternative to endoscopy in the assessment of postsurgical recurrence of Crohn's disease (CD). The object of this study was to evaluate the accuracy of abdominal ultrasonography (AUS) and (99m)Tc-hexamethylpropylene amineoxime ((99m)Tc-HMPAO)-labelled leucocyte scintigraphy (LLS) compared with endoscopy in the diagnosis and grading of postsurgical recurrence of CD. Between January 2006 and May 2007, all patients with CD and resection with ileocolic anastomosis were included prospectively. Within three days they underwent an ileocolonoscopy, AUS with evaluation of bowel wall thickness and the presence of Doppler flow, and LLS. Forty patients who met the study conditions were included; 5 patients did not agree to have the ileocolonoscopy and it was not possible to assess the anastomosis in 2 patients. Endoscopic recurrence was detected in 26 patients (78.8%), in 15 of whom it was moderate-severe. For the diagnosis of recurrence, both AUS and LLS showed acceptable sensitivity and positive predictive value, with an accuracy of 72.7% and 78.1%, respectively. The results of the AUS and LLS for diagnosing moderate-severe recurrence were better, with an accuracy of 78.8% and 81.3%, respectively. The best assessment of the severity of the recurrence was obtained with the combination of both techniques (sensitivity, specificity, positive and negative predictive values, accuracy and kappa index were, respectively: 93.3%, 72.2%, 73.7%, 92.9%, 81.8% and 0.64). The variables evaluated, both sonographic and scintigraphic, had areas under the curve that were similar and significantly different from 0.5. CONCLUSION: Abdominal ultrasonography and (99m)Tc-HMPAO-labelled leucocyte scintigraphy are two useful non-invasive techniques for the assessment of postsurgical recurrence of Crohn's disease.
    [Abstract] [Full Text] [Related] [New Search]