These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Safety profile of sequential transcatheter chemoembolization with DC Bead™: results of 237 hepatocellular carcinoma (HCC) patients. Author: Malagari K, Pomoni M, Spyridopoulos TN, Moschouris H, Kelekis A, Dourakis S, Alexopoulou E, Koskinas J, Angelopoulos M, Kornezos J, Pomoni A, Tandeles S, Marinis A, Rizos S, Kelekis D. Journal: Cardiovasc Intervent Radiol; 2011 Aug; 34(4):774-85. PubMed ID: 21184228. Abstract: INTRODUCTION: Complications of chemoembolization performed with DC Bead(™) loaded with doxorubicin (DEBDOX) of diameters 100-300 μm and 300-500 μm are presented in this paper. These diameters are currently the smallest available in drug-eluting technology. METHODS: Included are 237 patients who were treated with sequential DEBDOX with doxorubicin loaded at 37.5 mg/ml of DC Bead. The National Cancer Institute Common Terminology Criteria for Adverse Events (version 3.0) were used to categorize complications. RESULTS: Thirty-day mortality was 1.26% (3/237). Incidence of grade 5 complications was 1.26% (3/237). Overall, grade 4 complications resulted in 5.48% (13/237) (irreversible liver failure, cholecystitis). Grade 2 liver function deterioration developed in 10 patients (4.2%). Cholecystitis/grade 2 and 4 incidents were observed in 3.6-5.06% across sessions (overall 13 patients; 5.48%). Postembolization Syndrome (PES) grade 1 or 2 was observed in up to 86.5%; however, grade 2 was observed in 25-42.19% across treatments. Pleural effusion was seen in eight patients (overall 3.37%; grade 1 in 1.8-3.7% across treatments; grade 3 in 0.42%). Grade 1 procedure-related laboratory pancreatitis was seen in 0.45%, and grade 2 gastrointestinal bleeding was seen in 0.84%. Procedure-associated skin erythema/grade 1 was seen in 0.84%. There was no correlation of liver failure or transient liver function deterioration with the diameter of the beads (p = 0.25-0.37 and p = 0.14-0.89, respectively). Stratifying with the diameter of the beads correlation values was: for cholecystitis (p = 0.11-0.96 across treatments), PES (p = 0.35-0.83), temporary/grade 1 elevation of liver enzymes (p = 0.002-0.0001), and bilirubin (p = 0.04-0.99). CONCLUSIONS: DEBDOX chemoembolization is safe and small calibres do not result in increased complication rates compared with results of series using larger diameters of beads.[Abstract] [Full Text] [Related] [New Search]