These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Diagnostic performance of ADC for Non-mass-like breast lesions on MR imaging. Author: Imamura T, Isomoto I, Sueyoshi E, Yano H, Uga T, Abe K, Hayashi T, Honda S, Yamaguchi T, Uetani M. Journal: Magn Reson Med Sci; 2010; 9(4):217-25. PubMed ID: 21187691. Abstract: We assessed the usefulness and limitations of utilizing apparent diffusion coefficient (ADC) values on diffusion-weighted imaging (DWI) for the differential diagnosis of benign and malignant non-mass-like breast lesions. We retrospectively reviewed 27 such lesions (16 malignant, 11 benign) detected on magnetic resonance (MR) imaging and analyzed the enhancing patterns of dynamic contrast-enhanced DCE-MRI (distribution and internal enhancement), kinetic curve patterns, and ADC values. All images were obtained with a 1.5-tesla MR unit, with patients supine. On DCE-MRI, malignant lesions tended to show either segmental or branching-ductal distribution, and when lesions with these patterns were considered malignant, sensitivity was 68.8%; specificity, 63.6%; positive predictive value (PPV), 73.3%; negative predictive value (NPV), 58.3%; and accuracy, 66.7%. Kinetic curve analysis did not reliably differentiate benign and malignant non-mass-like lesions. There was no significant difference between the mean ADC value of the malignant lesions, 0.968 × 10(-3) mm(2)/s at b=1000 s/mm(2), and that of benign lesions, 1.207 × 10(-3) mm(2)/s (P=0.109). Receiver operating characteristic (ROC) analysis revealed the most effective threshold of ADC value for differentiating tumors as 1.1 × 10(-3) mm(2)/s; values lower than this were observed more often in malignant than benign lesions (P=0.054). Us of this threshold yielded sensitivity of 68.8%; specificity, 72.7%; PPV, 78.6%; NPV, 61.5%; and accuracy, 70.4%. Combining the ADC value criteria with the analysis of DCE-MRI pattern increased sensitivity to 93.8%, negative predictive value (NPV) to 85.7%, and accuracy to 77.8% but decreased specificity to 54.5%. Use of ADC values does not adequately improve DCE-MRI performance for differential diagnosis of non-mass-like breast lesions, but adding the ADC value criteria to the DCE-MRI pattern analysis improves sensitivity, NPV, and accuracy.[Abstract] [Full Text] [Related] [New Search]