These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Simultaneous quantification of levetiracetam and gabapentin in plasma by ultra-pressure liquid chromatography coupled with tandem mass spectrometry detection.
    Author: Juenke JM, Brown PI, Johnson-Davis KL, McMillin GA.
    Journal: Ther Drug Monit; 2011 Apr; 33(2):209-13. PubMed ID: 21297550.
    Abstract:
    INTRODUCTION: Gabapentin (Neurontin) and levetiracetam (Keppra) are anticonvulsants with novel structures and suggested therapeutic ranges of 2-10 mg/L and 6-20 mg/L, respectively. Gabapentin is also used extensively to manage neuropathic pain, and for this indication, wherein higher doses are prescribed, plasma concentrations of 15-30 mg/L are typical. OBJECTIVE: Here, we describe a simple rapid assay to support therapeutic drug monitoring of gabapentin and levetiracetam in plasma by ultra-pressure liquid chromatography couples to tandem mass spectrometry (UPLC-MS/MS) detection. METHODS: After the addition of internal standard and protein precipitation of patient plasma with methanol:acetonitrile in a 50:50 ratio, 1 μL of supernatant sample is injected onto an Acquity UPLC HSS T3, 1.8 μm, 2.1 × 50 mm (Waters) column. Elution occurs using a linear gradient of acetonitrile and water, each having 0.1% formic acid added. The column is eluted into a Waters Acquity UPLC TQD, operating in a positive mode to detect gabapentin at transition 172.18 > 154.11, levetiracetam at 171.11 > 126, and internal standard (3-amino-2-naphthoic acid) at 188.06 > 170. Secondary transitions for each analyte are also monitored for gabapentin at 172.18 > 137.06, levetiracetam at 171.11 > 154, and internal standard at 188.06 > 115. Runtime is 1.5 minutes per injection with baseline resolved chromatographic separation. RESULTS: The analytical measurement ranges were 1-150 mg/L for gabapentin and for levetiracetam. Intra-assay imprecision by the coefficient of variance (CV) was less than 8% and interassay CV was less than 5% for both analytes, at 4 different concentrations. Results obtained from patient samples were compared with results generated by established high-performance liquid chromatography-UV methods with the following regression statistics: y = 1.12x - 0.77, r = 0.996, Sy, x = 0.89, and n = 29 for gabapentin and y = 0.991x + 0.70, r = 0.997, Sy, x = 2.24, and n = 30 for levetiracetam. No analytical interferences were identified. CONCLUSION: : In summary, a simple reliable UPLC-MS/MS method was developed and validated for routine clinical monitoring of gabapentin and levetiracetam.
    [Abstract] [Full Text] [Related] [New Search]