These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Clinically unexpected cyclosporine levels using the ACMIA method on the RXL dimension analyser. Author: Morelle J, Wallemacq P, Van Caeneghem O, Goffin E. Journal: Nephrol Dial Transplant; 2011 Apr; 26(4):1428-31. PubMed ID: 21335442. Abstract: Safe use of cyclosporine (CsA) in solid organ transplantation relies on regular whole-blood drug monitoring. Several promising immmunoassays, e.g. the antibody-conjugated magnetic immunoassay (ACMIA) method, were developed and commercialized during recent years to compete with liquid chromatography coupled to tandem mass spectrometry, which remains the reference method but is labor-intensive. We describe the occurrence of interference in the monitoring of whole-blood CsA after transplantation when using the ACMIA method and discuss the potential mechanisms involved in such interference. Clinically unexpected results of whole-blood CsA require immediate reassessment by another technique to prevent the risk of CsA underdosage and graft rejection.[Abstract] [Full Text] [Related] [New Search]