These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Reversed root for entirely biological aortic valve and ascending aorta replacement in a patient with endocarditis and mediastinitis.
    Author: Albes JM, Claus T.
    Journal: Thorac Cardiovasc Surg; 2011 Jun; 59(4):247-8. PubMed ID: 21394712.
    Abstract:
    A 59-year-old patient developed endocarditis with coagulase-negative staphylococci after aortic composite graft replacement and pacemaker implantation. She underwent complete pacemaker removal and tricuspid valve reconstruction. Pus was present in and around the aortic graft. Re-replacement of the aortic root and ascending aorta using only biological material was performed. A 23-mm full root stentless prosthesis (Vascutek Root Elan, Vascutec, Terumo, Leeds, UK) was used for aortic root replacement, and a second 25-mm full root prosthesis with removed cusps implanted in a reversed fashion was used for ascending aorta and proximal aortic arch replacement.
    [Abstract] [Full Text] [Related] [New Search]