These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Pharmacokinetics of a sustained-release dexamethasone intravitreal implant in vitrectomized and nonvitrectomized eyes.
    Author: Chang-Lin JE, Burke JA, Peng Q, Lin T, Orilla WC, Ghosn CR, Zhang KM, Kuppermann BD, Robinson MR, Whitcup SM, Welty DF.
    Journal: Invest Ophthalmol Vis Sci; 2011 Jun 28; 52(7):4605-9. PubMed ID: 21421864.
    Abstract:
    PURPOSE: To evaluate dexamethasone pharmacokinetics after implantation of a sustained-release dexamethasone (DEX) intravitreal implant in nonvitrectomized and vitrectomized eyes. METHODS: The right eyes of 25 rabbits underwent vitrectomy; contralateral eyes served as nonvitrectomy controls. The 0.7-mg DEX implant was injected into both eyes, and drug concentrations were determined in the vitreous humor and retina for 31 days (on days 2, 8, 15, 22, and 31). RESULTS: DEX was present in nonvitrectomized and vitrectomized eyes for at least 31 days. There were no statistically significant differences in DEX concentration between nonvitrectomized and vitrectomized eyes at any time point (P > 0.05). The maximum concentration of DEX in nonvitrectomized versus vitrectomized eyes for vitreous humor was 791 ng/mL (day 22) versus 731 ng/mL (day 22), respectively, and for retina it was 4110 ng/mL (day 15) versus 3670 ng/mL (day 22), respectively. Mean absorption (AUC(0-tlast)) of dexamethasone in nonvitrectomized and vitrectomized eyes was not different for both the vitreous humor (13,600 vs. 15,000 ng/day/mL; P = 0.73) and retina (67,600 vs. 50,200 ng/day/mL; P = 0.47). CONCLUSIONS: The vitreoretinal pharmacokinetic profiles were similar between nonvitrectomized and vitrectomized eyes. These observations are consistent with clinical findings of the DEX implant in patients who have undergone vitrectomy and should reduce concerns about the use of the DEX implant in eyes that have undergone vitrectomy.
    [Abstract] [Full Text] [Related] [New Search]