These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Determination of endogenous concentrations of N1-methylnicotinamide in human plasma and urine by high-performance liquid chromatography. Author: Somogyi A, Siebert D, Bochner F. Journal: Anal Biochem; 1990 May 15; 187(1):160-5. PubMed ID: 2142586. Abstract: A high-performance liquid chromatographic assay for the determination of endogenous plasma and urine concentrations of N1-methylnicotinamide was developed. N1-Methylnicotinamide and N1-ethylnicotinamide (internal standard) are reacted with acetophenone in a strong base at 0 degree C, formic acid is added, and the reaction mixture is heated in a boiling water bath, resulting in the formation of fluorescent derivatives. These derivatives were chromatographed on a C18 reverse-phase column using a mobile phase of acetonitrile-triethylamine and 0.01 M heptanesulfonic acid adjusted to pH 3.2. Fluorescent detection was achieved using 366-nm excitation and 418-nm emission filters. Precision and accuracy were generally greater than 90%, interfering peaks did not cochromatograph, and the limit of quantification was 2 ng/ml in plasma using a 0.2-ml sample. The method was used to examine the concentrations of endogenous N1-methylnicotinamide in the plasma of 36 subjects with various pathology. The mean concentration was 18 ng/ml and the range was 6.2 to 116.7 ng/ml. The assay represents a marked improvement on previous methods and is suitable for routine clinical monitoring.[Abstract] [Full Text] [Related] [New Search]