These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Preliminary study on polyvinyl alcohol/wild antheraea pernyi silk fibroin as nanofiber scaffolds for tissue engineered tendon].
    Author: Wu L, Li M, Zhao J, Chen D, Zhou Z.
    Journal: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Feb; 25(2):181-6. PubMed ID: 21427847.
    Abstract:
    OBJECTIVE: To investigate the cellular compatibility of polyvinyl alcohol (PVA)/wild antheraea pernyi silk fibroin (WSF), and to explore the feasibility for tendon tissue engineering scaffold in vitro. METHODS: The solutions of WSF (11%), PVA (11%), and PVA/WSF (11%) were prepared with 98% formic acid (mass fraction) at a mass ratio of 9:1. The electro spinning membranes of WSF, PVA, and PVA/WSF were prepared by electrostatic spinning apparatus. The morphologies of scaffolds were evaluated using scanning electronic microscope (SEM). The tendon cells were isolated from tail tendon of 3-day-old Sprague Dawley rats in vitro. The experiment was performed using the 3rd generation cells. The tendon cells (1 x 10(6)/mL) were cocultured with PVA and PVA/WSF electro spinning film, respectively, and MTT test was used to assess the cell adhesion rate 4, 12 hours after coculture. The tendon cells were cultured in PVA and PVA/WSF extraction medium of different concentration (1, 1/2, and 1/4), respectively; and the absorbance (A) values were detected at 1, 3, 5, and 7 days to evaluate the cytotoxicity. The composite of tendon cells and the PVA or PVA/WSF scaffold were observed by HE staining at 7 days and characterized by SEM at 1, 3, 5, and 7 days. RESULTS: The solution of WSF could not be used to electro spin; and the solution of PVA and PVA/WSF could be electrospun. After coculture of tendon and PVA or PVA/WSF electro spinning membranes, the cell adhesion rates were 26.9% +/- 0.4% and 87.0% +/- 1.0%, respectively for 4 hours, showing significant difference (t = 100.400, P = 0.000); the cell adhesion rates were 35.2% +/- 0.6% and 110.0% +/- 1.7%, respectively for 12 hours, showing significant difference (t = 42.500, P = 0.000). The cytotoxicity of PVA/WSF was less significantly than that of PVA (P < 0.05) and significant difference was observed between 1/2 PVA and 1/4 PVA (P < 0.05). HE staining and SEM images showed that the tendon cells could adhere to PVA and PVA/WSF scaffolds, but that the cells grew better in PVA/WSF scaffold than in PVA scaffold in vitro. CONCLUSION: PVA/WSF electro spinning membrane scaffold has good cell compatibility, and it is expected to be an ideal scaffold of tendon tissue engineering.
    [Abstract] [Full Text] [Related] [New Search]