These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Extremely sensitive detection of NO₂ employing off-axis integrated cavity output spectroscopy coupled with multiple-line integrated absorption spectroscopy.
    Author: Rao GN, Karpf A.
    Journal: Appl Opt; 2011 May 01; 50(13):1915-24. PubMed ID: 21532674.
    Abstract:
    We report on the development of a new sensor for NO₂ with ultrahigh sensitivity of detection. This has been accomplished by combining off-axis integrated cavity output spectroscopy (OA-ICOS) (which can provide large path lengths of the order of several kilometers in a small volume cell) with multiple-line integrated absorption spectroscopy (MLIAS) (where we integrate the absorption spectra over a large number of rotational-vibrational transitions of the molecular species to further improve the sensitivity). Employing an external cavity quantum cascade laser operating in the 1601-1670 cm⁻¹ range and a high-finesse optical cavity, the absorption spectra of NO₂ over 100 transitions in the R band have been recorded. From the observed linear relationship between the integrated absorption versus concentration of NO₂ and the standard deviation of the integrated absorption signal, we report an effective sensitivity of detection of approximately 28 ppt (parts in 10¹²) for NO₂ To the best of our knowledge, this is among the most sensitive levels of detection of NO₂ to date.
    [Abstract] [Full Text] [Related] [New Search]