These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Two-year follow-up of the Genous™ endothelial progenitor cell capturing stent versus the Taxus Liberté stent in patients with de novo coronary artery lesions with a high-risk of restenosis: a randomized, single-center, pilot study.
    Author: Beijk MA, Klomp M, van Geloven N, Koch KT, Henriques JP, Baan J, Vis MM, Tijssen JG, Piek JJ, de Winter RJ.
    Journal: Catheter Cardiovasc Interv; 2011 Aug 01; 78(2):189-95. PubMed ID: 21542109.
    Abstract:
    BACKGROUND: In the prospective randomized TRIAS pilot study, the bio-engineered Genous™ endothelial progenitor cell capturing stent was compared with the Taxus Liberté™ SR paclitaxel-eluting stent. At 1 yr, a statistically nonsignificant difference in the rates of target vessel failure (cardiac death, myocardial infarction, or target vessel revascularization) was observed. We have evaluated the safety and efficacy up to 2 yr. METHODS: A total of 193 patients with de novo coronary artery lesions carrying a high risk of restenosis were randomized to a Genous stent versus a Taxus stent. Dual antiplatelet therapy was prescribed for ≥1 month after Genous stent implantation and for ≥6 months after a Taxus stent. RESULTS: Between 1 and 2 yr, patients treated with the Genous stent tended to have fewer episodes of target lesion revascularization (2.0% versus 5.3%), but nearly similar rates of cardiac death (1.0% versus 0%), myocardial infarction (0% versus 1.1%), and stent thrombosis (0% versus 1.1%) when compared with the Taxus stent. As a result, at 2-yr follow-up treatment with the Genous stent compared with the Taxus stent resulted in a nonsignificant difference in target vessel failure (TVR) (20.4% versus 15.8%; risk difference 4.6%, 95% CI -6.2-15.5%). No stent thrombosis was observed in the Genous group compared to five cases (in four patients) in the Taxus group, resulting in a difference as compared with the Taxus stent (risk difference -4.2%; 95%CI -8.2% to -0.2%). CONCLUSIONS: In the TRIAS pilot study, treatment of coronary artery lesions carrying a high risk of restenosis with the Genous compared with the Taxus stent resulted in a nonsignificant difference of TVR at 2-yr follow-up, with convergence of the Kaplan-Meier curves between 1 and 2 yr. Stent thrombosis was only observed after Taxus stent implantation.
    [Abstract] [Full Text] [Related] [New Search]