These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The role of ultrahigh-frequency audiometry in the early detection of systemic drug-induced hearing loss.
    Author: Singh Chauhan R, Saxena RK, Varshey S.
    Journal: Ear Nose Throat J; 2011 May; 90(5):218-22. PubMed ID: 21563089.
    Abstract:
    In monitoring patients for drug-induced hearing loss, most audiometric evaluations are limited to the range of frequencies from 0.25 to 8 kHz. However, such testing would fail to detect ototoxicity in patients who have already experienced hearing loss in the ultrahigh frequencies from 10 to 20 kHz. Awareness of ultrahigh-frequency ototoxicity could lead to changes in a drug regimen to prevent further damage. We conducted a prospective study of 105 patients who were receiving a potentially ototoxic drug-either gentamicin, amikacin, or cisplatin-to assess the value of ultrahigh-frequency audiometry in detecting systemic drug-induced hearing loss. We found that expanding audiometry into the ultrahigh-frequency range led to the detection of a substantial number of cases of hearing loss that would have otherwise been missed.
    [Abstract] [Full Text] [Related] [New Search]