These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Optimization of a HPLC determination method for Evodia rutaecarpa].
    Author: Huang Z, Yi J, Wu Y, Liu Y, Chen Y, Liu Y.
    Journal: Zhongguo Zhong Yao Za Zhi; 2011 Feb; 36(4):478-80. PubMed ID: 21598546.
    Abstract:
    A HPLC method for determination of limonin, evodiamine and rutaecarpine in Evodia rutaecarpa was optimized. The mobile phase was [acetonitrile-tetrahydrofuran (25: 15)] -0.02% H3 PO4 (35:65). The detection wavelength was 220 nm and the flow rate was 1.0 mL x min(-1). Limonin, evodiamine and rutaecarpine were all well separated from other substances and their UV spectrums were essentially the same to the standards . The liner ranges of limonin, evodiamine and rutaecarpine were 0.196 8-3.936, 0.153 6-3.072, 0.097 4-1.948 microg. The average recoveries were 97.8%, 100.7% and 98.4%. RSD were 1.7%, 1.3% and 1.1% (n = 6). The method of this article is accurate, reproducible and can be used to enhance the quality control of E. rutaecarpa.