These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effect of pressure support on end-expiratory lung volume and lung diffusion for carbon monoxide. Author: Pinto Da Costa N, Di Marco F, Lyazidi A, Carteaux G, Sarni M, Brochard L. Journal: Crit Care Med; 2011 Oct; 39(10):2283-9. PubMed ID: 21666442. Abstract: OBJECTIVES: The level of pressure-support ventilation can affect mean airway pressure and potentially lung volume, but its increase is usually associated with a reduced respiratory rate, and the net effects on the gas exchange process and its components, including end-expiratory lung volume, have not been carefully studied. We measured pulmonary conductance for gas exchange based on lung diffusion for carbon monoxide in patients receiving pressure-support ventilation. DESIGN: Prospective, randomized, crossover study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: Sixteen patients mechanically ventilated in pressure-support ventilation mode and free from chronic obstructive pulmonary disease. INTERVENTIONS: Two pressure-support ventilation levels (5 cm H2O difference) at the same level of positive end-expiratory pressure. MEASUREMENTS AND MAIN RESULTS: End-expiratory lung volume, lung diffusion for carbon monoxide, and SpO2/Fio2 were evaluated. Increasing pressure-support ventilation by 5 cm H2O significantly increased the mean tidal volume from 6.8 to 8.5 mL/kg of predicted body weight and decreased the mean respiratory rate by 6.6 breaths per minute. Although SpO2/Fio2 did not change significantly, there was a slight but significant decrease in lung diffusion for carbon monoxide (average decay rate of 4.5%) at high pressure-support ventilation. The pressure-support ventilation level did not significantly affect end-expiratory lung volume (1737±629 mL at 9.6±2.5 cm H2O pressure-support ventilation level vs. 1749±657 mL at 14.9±2.1 cm H2O pressure-support ventilation level). CONCLUSIONS: A 5-cm H2O increase in pressure-support ventilation neither affected end-expiratory lung volume nor increased the pulmonary volume participating in gas exchange. A target tidal volume closer to 6 mL/kg of predicted body weight than to 8 mL/kg during pressure-support ventilation was associated with better gas exchange.[Abstract] [Full Text] [Related] [New Search]