These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Retrospective measurements of thoron and radon by CDs/DVDs: a model approach. Author: Pressyanov DS. Journal: Radiat Prot Dosimetry; 2012 May; 149(4):464-8. PubMed ID: 21778159. Abstract: An approach for retrospective measurements of thoron ((220)Rn) and radon ((222)Rn) by home-stored CDs/DVDs is proposed. It employs analysis of alpha tracks at two depths beneath the disk surface. The signal in the first one (69 µm) is due both to (220)Rn and (222)Rn, while the signal at the second (80 µm) is due only to (222)Rn. The second signal is used as to measure (222)Rn, as well as to determine and subtract 'the (222)Rn component' from the first signal. The remaining '(220)Rn component' is used to measure thoron. Numerical modelling is performed and the results show that simultaneous retrospective measurements of thoron and radon are possible over a wide range of environmental concentrations.[Abstract] [Full Text] [Related] [New Search]