These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Current issues in central venous catheter infection. Author: Toltzis P, Goldmann DA. Journal: Annu Rev Med; 1990; 41():169-76. PubMed ID: 2184721. Abstract: The majority of central venous line-associated infections are caused by organisms on the skin near the exit site gaining access to the intravascular segment of the catheter. A variety of strategies have been used in an effort to reduce catheter contamination, but one innovation--the semipermeable transparent dressing--may actually increase infection risk. On the other hand, new catheter materials and designs probably reduce the risk. There are only a limited number of well-designed studies of the increasingly popular totally implantable catheter system and the multilumen line, but it appears that the former is associated with a low rate of infection, while the latter may be more hazardous than the single-lumen line.[Abstract] [Full Text] [Related] [New Search]