These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Auto-PEEP and dynamic hyperinflation in COPD patients during controlled mechanical ventilation and high frequency jet ventilation.
    Author: Conti G, Bufi M, Rocco M, Calzecchi E, De Blasi RA, Antonelli M, Pelaia P, Gasparetto A.
    Journal: Intensive Care Med; 1990; 16(2):81-4. PubMed ID: 2185290.
    Abstract:
    We investigated the levels of auto-PEEP and dynamic hyperinflation during high frequency jet ventilation (HFJV) and controlled mechanical ventilation (CMV) in six patients with chronic obstructive pulmonary disease within the first 36 h of acute exacerbation. The comparative evaluation was performed at similar conditions of gas exchange in HFJV and CMV: PaO2 77.6 +/- 11 mmHg vs 80.8 +/- 12 mmHg; PaCO2 46.8 +/- 2.5 mmHg vs 47 +/- 2.8 mmHg; pH 7.38 vs 7.38. In this situation, the values of auto-PEEP and dynamic hyperinflation, expressed as delta over the apneic functional residual capacity (FRC) did not differ: (auto-PEEPHFJV 8.9 +/- 3.8 cmH2O; auto-PEEPCMV 8.8 +/- 4.7 cmH2O; delta FRCHFJV 0.56 +/- 0.19 l; delta FRCCMV 0.54 +/- 0.2 l). This result suggests that, with a suitable machine setting and similar gas exchanges, HFJV produces the same level of auto-PEEP and dynamic hyperinflation as CMV in patients with chronic obstructive pulmonary disease.
    [Abstract] [Full Text] [Related] [New Search]