These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: In vitro analysis of type II endoleaks and aneurysm sac pressurization on longitudinal stent-graft displacement. Author: Knowles M, Pellisar T, Murphy EH, Stanley GA, Hashmi AF, Arko MZ, Arko FR. Journal: J Endovasc Ther; 2011 Aug; 18(4):601-6. PubMed ID: 21861753. Abstract: PURPOSE: To evaluate the effects of type II endoleaks and sac pressurization on stent-graft displacement following endovascular aneurysm repair (EVAR). METHODS: Experimental silicone infrarenal aneurysm (6-cm) models were "treated" with a Talent stent-graft deployed with 20-mm proximal and distal landing zones. Inflow and outflow vessels were created as part of the silicone model to control flow into the aneurysm sac. All aneurysm models were uniform, with a diameter neck of 31 mm, a neck length of 20 mm, and iliac artery diameters of 16 mm. The aortic model was secured in a water bath to a pulsatile pump under physiological conditions; the output phase ratio (%systole/%diastole) was set at 65/35 with a pump rate of 80 beats per minute. Commercially available bifurcated stent-grafts were then displaced in vitro utilizing a linear motion apparatus attached to a force gauge. The mean arterial pressure (MAP) and pulse pressure (PP) at the aortic inflow were 60.1 ± 3.1 and 38.3 ± 7.8 mmHg, respectively. Peak force to cause initial stent-graft migration with and without a type II endoleak was recorded and compared. RESULTS: In aneurysm sacs with no endoleak, the MAP and sac PP were 32 ± 6.4 and 6 ± 1.3 mmHg, respectively (p<0.01). In aneurysm sacs with a type II endoleak, the MAP and sac PP were 54.1 ± 9.7 and 16.1 ± 4.1 mmHg, respectively (p<0.02). Peak force to initiate migration was 16.0 ± 1.41 N (range 15-18) with no endoleak vs. 23.2 ± 2.2 N (range 20-25) in those with a type IIa endoleak and 23.5 ± 2.5 N (range 20-26) in those with a type IIb endoleak (p<0.001). CONCLUSION: Type II endoleaks are associated with a significantly increased sac pressure. Increased sac pressurization from type II endoleaks results in a significantly greater force to displace a stent-graft longitudinally. Type II endoleaks may therefore inhibit migration and offer a benefit following EVAR; however, clinical correlation of these results is required.[Abstract] [Full Text] [Related] [New Search]