Search MEDLINE/PubMed
Title: EEG use in a tertiary referral centre. Author: O'Toole O, Lefter S, McNamara B. Journal: Ir Med J; 2011; 104(7):202-4. PubMed ID: 21957686. Abstract: The aim of this study was to retrospectively audit all electroencephalograms (EEGs) done over a 2-month period in 2009 by the Neurophysiology Department at Cork University Hospital. There were 316 EEGs performed in total, of which 176/316 (56%) were done within 24 hours of request. Out of 316 EEGs, 208 (66%) were considered 'appropriate' by SIGN and NICE guidelines; 79/208 (38%) had abnormal EEGs and 28 of these abnormal EEGs had epileptiform features. There were 108/316 (34%) 'inappropriate' requests for EEG; of these 15/108 (14%) were abnormal. Of the 67/316 (21%) patients who had EEGs requested based on a history of syncope/funny turns: none of these patients had epileptiform abnormalities on their EEGs. Our audit demonstrates that EEGs are inappropriately over-requested in our institution in particular for cases with reported 'funny turns' and syncope. The yield from EEGs in this cohort of patients was low as would be expected.[Abstract] [Full Text] [Related] [New Search]