These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Long-term evaluation of biological versus mechanical prosthesis use at reoperative aortic valve replacement. Author: Chan V, Lam BK, Rubens FD, Hendry P, Masters R, Mesana TG, Ruel M. Journal: J Thorac Cardiovasc Surg; 2012 Jul; 144(1):146-51. PubMed ID: 21962842. Abstract: OBJECTIVES: Recent evidence indicated that the use of a bioprosthesis in young patients at first-time aortic valve replacement (AVR) is associated with an increased reoperation risk, but not with an increase in long-term mortality, when compared with the use of a mechanical valve. However, at reoperative AVR, follow-up data by prosthesis type have been lacking from the literature. Therefore, we examined long-term survival and valve-related complications according to the type of prosthesis used at reoperative AVR. METHODS: We studied 437 patients who underwent reoperative AVR, at a mean age of 58.6 ± 14.2 years, for failure of a previously implanted aortic valve prosthesis. Thirty-day mortality at reoperative AVR was 6% (n = 27). A bioprosthesis was used in 135 (31%) patients. Patients were subsequently followed up for a mean of 7.6 ± 6.8 years after reoperative AVR. RESULTS: The use of a bioprosthesis at reoperative AVR was not associated with impaired survival on adjusted analysis (hazard ratio [HR], 0.8 ± 0.4; P = .6). Freedom from thromboembolism, and endocarditis were similar between valve types (both P > .05); however, late postoperative major hemorrhage occurred only in patients who received a mechanical prosthesis at reoperative AVR. Risk factors for third-time AVR included the use of a bioprosthesis (HR, 14.0) and younger age (HR, 1.05 per decreasing year) at reoperative AVR (both P < .001). Thirty-day mortality of third-time AVR was 4% (n = 1/27). CONCLUSIONS: At reoperative AVR, the use of a bioprosthesis is associated with equivalent long-term survival compared with a mechanical prosthesis. Patients who receive a bioprosthesis at reoperative AVR are less likely to experience major hemorrhage but more likely to require third-time AVR, albeit with an acceptable third-time perioperative mortality risk. Therefore, the patient's informed preferences regarding prosthesis choice should prevail, even in a reoperative context.[Abstract] [Full Text] [Related] [New Search]