These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Transduction of glycan-lectin binding using near-infrared fluorescent single-walled carbon nanotubes for glycan profiling. Author: Reuel NF, Ahn JH, Kim JH, Zhang J, Boghossian AA, Mahal LK, Strano MS. Journal: J Am Chem Soc; 2011 Nov 09; 133(44):17923-33. PubMed ID: 21970594. Abstract: There is significant interest in developing new detection platforms for characterizing glycosylated proteins, despite the lack of easily synthesized model glycans or high affinity receptors for this analytical problem. In this work, we demonstrate a sensor array employing recombinant lectins as glycan recognition sites tethered via Histidine tags to Ni(2+) complexes that act as fluorescent quenchers for semiconducting single-walled carbon nanotubes (SWNTs) embedded in a chitosan hydrogel spot to measure binding kinetics of model glycans. We examine, as model glycans, both free and streptavidin-tethered biotinylated monosaccharides. Two higher-affined glycan-lectin pairs are explored: fucose (Fuc) to PA-IIL and N-acetylglucosamine (GlcNAc) to GafD. The dissociation constants (K(D)) for these pairs as free glycans (106 and 19 μM, respectively) and streptavidin-tethered (142 and 50 μM respectively) were found. The absolute detection limit for the current platform was found to be 2 μg of glycosylated protein or 100 ng of free glycan to 20 μg of lectin. Glycan detection (GlcNAc-streptavidin at 10 μM) is demonstrated at the single nanotube level as well by monitoring the fluorescence from individual SWNT sensors tethered to GafD lectin. Over a population of 1000 nanotubes, 289 of the SWNT sensors had signals strong enough to yield kinetic information (K(D) of 250 ± 10 μM). We are also able to identify the locations of "strong transducers" on the basis of dissociation constant (four sensors with K(D) < 10 μM) or overall signal modulation (eight sensors with >5% quench response). We report the key finding that the brightest SWNTs are not the best transducers of glycan binding. SWNTs ranging in intensity between 50 and 75% of the maximum show the greatest response. The ability to pinpoint strong-binding, single sensors is promising to build a nanoarray of glycan-lectin transducers as a high throughput method to profile glycans without protein labeling or glycan liberation pretreatment steps.[Abstract] [Full Text] [Related] [New Search]