These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Determination of three sweeteners in vinegars by solid phase extraction-high performance liquid chromatography/tandem mass spectrometry]. Author: Yin F, Ding Z, Cao X, Gao J, Jiang D, Kuang D, Gu Y, He G. Journal: Se Pu; 2011 Jun; 29(6):554-7. PubMed ID: 22032168. Abstract: A solid phase extraction-high performance liquid chromatography/electrospray ionization-tandem mass spectrometry (SPE-HPLC/ESI-MS/MS) method for the determination of 3 sweeteners (acesulfame (AK), sodium saccharin (SA), sodium cyclamate (SC)) in vinegars has been developed. The sample was diluted with acidic water, then purified and enriched with a weak anion exchange SPE column. The HPLC separation was performed on a Pursuit C18 column (150 mm x 2.0 mm, 3 microm) by gradient elution with 10 mmol/L ammonium acetate containing 0.1% (v/v) ammonia water and acetonitrile as the mobile phases. The analytes were detected by ESI--MS/MS in multiple reaction monitoring (MRM) mode to satisfy qualitative and quantitative detections. Good linearities (r2 > 0.99) were obtained over the range of 0.01 - 0.50 mg/L. The limits of quantification (LOQs) for SA, AK and SC were 10, 5 and 5 microg/kg, respectively. The average recoveries ranged from 72.1% to 96.8% at the spiked levels of 0.01 and 0.1 mg/L with the relative standard deviations (RSDs) less than 15%. This method is accurate, highly sensitive for qualitative and quantitative analysis of the 3 sweeteners in vinegars.[Abstract] [Full Text] [Related] [New Search]