Title: Causes of rejection of blood samples handled in the clinical laboratory of a University Hospital in Porto Alegre. Author: Guimarães AC, Wolfart M, Brisolara ML, Dani C. Journal: Clin Biochem; 2012 Jan; 45(1-2):123-6. PubMed ID: 22040813. Abstract: OBJECTIVE: Errors in clinical laboratories have a great impact on safety and care of patients. The pre-analytical phase is responsible for about 70% of errors. Hence, the objective was to determine what types of pre-analytical errors for improvements at this stage, and contribute data to the literature. DESIGN AND METHODS: Every three months during the study, the rejected blood samples were assessed for type of pre-analytical error and home care. RESULTS: 77,051 blood samples were collected in the search period, whereof 441 (0.57%) were rejected by some type of pre-analytical error and therefore had to be recollected. Clot was found to be the major cause of rejection of samples, 43.8%, followed by insufficient sample volume, 24%. CONCLUSION: This study has shown that the most frequent causes of pre-analytical errors and rejection of samples corroborate those found in the literature.[Abstract] [Full Text] [Related] [New Search]