  • Title: [New methods of interlaboratory monitoring of HIV-1 ELISA kits. Comparative study of 2 periods: 1/12/1988 to 15/4/1989 and 15/4/1989 to 31/8/1989. Le Groupe Rétrovirus de la Sociètè Nationale de Transfusion Sanguine].
    Author: North ML, Noël L, Couroucé AM.
    Journal: Rev Fr Transfus Hemobiol; 1990 Jun; 33(3):211-22. PubMed ID: 2206168.
    Abstract:
    Since december 1st 1988, the Retrovirus study Group of the French Society of Blood Transfusion has initiated a systematic multicentric control of all anti-HIV screening EIA test kits lots used by each member of the group. For this purpose a special panel (GRV) has been designed and forwarded to each laboratory. From december 1st 1988 to august 8 1989, 6 HIV-1 kits have been in use (Diagnostics Pasteur Elavia 1; Diagnostics Pasteur Rapid'Elavia; Organon Vironostika; Abbott HIV recombinant; Du Pont env 9; Wellcome Wellcozyme). The GRV panel has been run 204 times on 102 different lots in 12 laboratories. Results after 9 months show that these 6 kits almost always properly recognize the 5 HIV 1 positive samples of the panel. However they differ in their ability to recognize HIV 2 positive samples. Variations in results are observed from lot to lot as well as between the first half of this period and the second.