Search MEDLINE/PubMed
Title: A cylindrical traveling wave ultrasonic motor using a circumferential composite transducer. Author: Liu Y, Liu J, Chen W. Journal: IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Nov; 58(11):2397-404. PubMed ID: 22083773. Abstract: This paper intends to present and verify a new idea for constructing traveling wave ultrasonic motors that may effectively avoid the drawbacks of conventional traveling wave motors using bonded PZT plates as the exciting elements. In the configuration of the motor's stator, a composite sandwich type transducer is used to excite a traveling wave in a cylinder with two cantilevers as the coupling bridges between the transducer and the cylinder. The design process of the stator is described using the FEM modal analysis method, and the establishment of traveling wave on the cylindrical stator was simulated by FEM transient analysis. To verify the theoretical analysis results, a laser Doppler scanner was employed to test the mode shapes of a prototype stator excited by the longitudinal and bending vibrations respectively. Finally, to validate the design idea, a prototype motor was fabricated and tested; the typical output features are no-load speed of 156 rpm and maximum torque of 0.75 N·m under exciting voltages of 70 V(rms) applied to excite the longitudinal vibration of the transducer and 200 V(rms) applied to excite the bending vibration.[Abstract] [Full Text] [Related] [New Search]