These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography--a prospective randomized trial.
    Author: Yuan R, Shuman WP, Earls JP, Hague CJ, Mumtaz HA, Scott-Moncrieff A, Ellis JD, Mayo JR, Leipsic JA.
    Journal: Radiology; 2012 Jan; 262(1):290-7. PubMed ID: 22084206.
    Abstract:
    PURPOSE: To compare quantitative and subjective image quality and radiation dose between standard computed tomographic (CT) pulmonary angiography (CTPA) and CTPA with a dual-energy technique with reduced iodine load. MATERIALS AND METHODS: This prospective study was approved by the institutional review board and each participant provided informed consent. Ninety-four patients (59% male; mean age ± standard deviation, 62 years ± 15) were randomized to one of two protocols: standard CTPA (100-120 kVp) with standard contrast medium injection (n = 46) and dual-energy CTPA (image reconstruction at 50 keV) with the same injection volume as in the standard protocol but composed of contrast medium and saline in a 1:1 fashion, resulting in 50% reduction in iodine load (n = 48). Signal intensity and noise in three central and two segmental pulmonary arteries were measured; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate vascular enhancement and image noise. The proportion of diagnostic (score, ≥ 3) studies and the interreader agreement regarding the dichotomized diagnostic versus nondiagnostic scale were compared between the two groups. RESULTS: Compared with standard CTPA, dual-energy CTPA demonstrated higher signal intensity in all pulmonary arteries (all P < .01), inferior noise only in segmental arteries (P < .05), higher SNR and CNR (both P < .05), and compatible effective dose (P > .05). The five-point score was higher in the standard CTPA protocol (P < .05). The interreader agreement regarding the dichotomized diagnostic versus nondiagnostic scale was similar (P > .05) between the two groups. CONCLUSION: Dual-energy CTPA with image reconstruction at 50 keV allows a significant reduction in iodine load while improving intravascular signal intensity, maintaining SNR and with comparable radiation dose.
    [Abstract] [Full Text] [Related] [New Search]