These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: European multi-centre comparison of thallium 201 and technetium 99m methoxyisobutylisonitrile in ischaemic heart disease. Author: Maisey MN, Lowry A, Bischof-Delaloye A, Fridrich R, Inglese E, Khalil MN, van der Schoot JB. Journal: Eur J Nucl Med; 1990; 16(12):869-72. PubMed ID: 2209656. Abstract: Fifty-six patients in Europe were entered into a multi-centre study to compare the accuracy of technetium 99m methoxyisobutylisonitrile (99mTc-MIBI) for the detection of coronary artery disease (CAD) with thallium 201 (201Tl) chloride perfusion scanning. The results showed a high degree of concordance between the two radiopharmaceuticals. Some 81% (678/840) of myocardial segments showed the same result (normal, infarct or ischaemia), and 80% (45/56) of patients had the same diagnosis. Overall detection of CAD in patients was 98% for 201T1 and 96% for 99mTc-MIBI. Detection of CAD in total arteries was 68% for both agents. In this study 99mTc-MIBI was as accurate as 201Tl for the detection of coronary artery stenoses.[Abstract] [Full Text] [Related] [New Search]