These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Determination of 23 organochlorine pesticides in soil and sediment by gas chromatography coupled with dual columns and dual electron capture detectors].
    Author: Zhu H, Liu W, Ding X, Zhao Y.
    Journal: Se Pu; 2011 Aug; 29(8):773-80. PubMed ID: 22128742.
    Abstract:
    Gas chromatography (GC) coupled with dual columns and dual electron capture detectors (ECD) was established to determine 23 organochlorine pesticides in 5 soil and 5 sediment samples. Microwave assisted extraction and solid phase extraction with a Florisil column and sulfur cleanup with copper powder were used in sample pre-processing. Chromatographic analysis was performed on DB-XLB and DB-1701 capillary columns by internal standard method. This method showed good extraction efficiency, high sensitivity and good reproducibility. In the same linear range of 0.005 - 0.5 mg/L of 23 pesticides, the correlation coefficients were higher than 0.997. The average spiked recoveries were 50% - 119% with the relative standard deviations (RSDs) of 0.9% - 16.1% (n = 6) in 5 soil samples, and were 52% - 120% with RSDs of 0.3% - 28.4% ( n = 6) in 5 sediment samples, respectively. The detection limits were 0.000 05 -0.000 5 mg/kg. The results indicate that this method is suitable for the determination of the 23 organochlorine pesticides in soil and sediment samples.